Synthes va prox tibia inventory

The Synthes 4.5 mm LCP Proximal Tibia Plate are indicated for the treatment of nonunions, malunions and fractures of the proximal tibia including: simple comminuted, lateral wedge, depression, medial wedge, bicondylar, combi ... Customers were asked to review their inventory for the affected lots, call DePuy Synthes at 1-800-479-6329 to obtain ...

Insert the internal fixator between the anterior tibial muscle and the periosteum. Slide the LISS plate in the distal direction with its distal end in constant contact with the bone. Position the proximal end of the fixator against the lateral condyle. Carefully find the correct posi-tion of the LISS on the condyle.Plates, Distal Tibia T- and L-Plates and Distal Fibula Plates. 2.7 mm VA LOCKING CALCANEAL PLATES The pre-contoured, low-profile plates with variable angle (VA) screw placement are designed to reduce the likelihood of soft tissue irritation along the lateral calcaneal wall, with VA locking screws seated flush in the plate.

Did you know?

Also included in Synthes 3.5 mm Cannulated Screw Instrument and Implant Set (105.03). Includes a range of short thread and long thread 3.5 mm Cannulated Screws. CLICK HERE for a full list of 3.5 mm Cannulated Screws. See close-up of 205.224 and 205.024 below.The Variable Angle LCP™ Curved Condylar Plate is a distal femur implant designed to address multiple patient anatomies, fracture patterns and surgical situations including supracondylar, intra-articular and extra-articular condylar fractures, and periprosthetic fractures. Product Specifications. How to Use This Product.DESCRIPTION. The LCP™ Locking Attachment Plate offers an alternative to cerclage cables and uses a connecting screw to augment the stabilization of fractures. The locking capability stabilizes fixed-angle constructs in periprosthetic fractures, and fractures in the presence of intramedullary implants. Product Specifications.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J7510-C 11/13 Inventory Control Form LCP Distal Femur and LCP Proximal Lateral …

4ePuy D Synthes 3.5 mm LCP® Clavicle Hook Plates Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, whichTitanium Cannulated Tibial Nails-EX, with Proximal bend, sterile Patient Information: J7976-F 5/13 Inventory Control Form Titanium Cannulated Tibial Nail-EX, with Proximal bend 8.0 mm diameter LENGTH LENGTH 04.034.231S 255 mm 04.034.234S 270 mm 04.034.237S 285 mm 04.034.240S 300 mm 04.034.243S 315 mmA fracture, or break, in the shinbone just below the knee is called a proximal tibia fracture. The proximal tibia is the upper portion of the bone where it widens to help form the knee joint. In addition to the broken bone, soft tissues (skin, muscle, nerves, blood vessels, and ligaments) may be injured at the time of the fracture.The Arthrex Distal Tibia Plating System was designed for the versatile treatment of distal tibia fractures.• Includes anterolateral, medial, anterior, and posterior tibia plates; 2.7 mm straight plates; and two styles of posterolateral fibula plates• Particular attention was placed on maintaining a low-profile design by optimizing contour and fit to minimize soft-tissue …At DePuy Synthes, our mission is to keep people moving through innovations in orthopaedic surgery, support and education for providers, and a dedication to improving diversity, inclusivity, and equality throughout the healthcare system. With new advancements in orthopaedic devices, medical technology, and digital surgery across the continuum of care, we are proud to provide surgeons with ...

Inventory Control Form 2.7 mm Variable Angle LCP® Clavicle Plate System 2.7 mm VA LCP Clavicle Plates Lateral Stainless Steel Titanium Plate Size Left/Right 02.112.61004.112.610 Left CS1 02.112.61104.112.611 Right CS1 02.112.61204.112.612 Left CS2 02.112.61304.112.613 Right CS2 02.112.61404.112.614 Left CS3 02.112.61504.112.615 Right CS3TN-ADVANCED™ Tibial Nailing System. Product Codes: 03.043.002, 03.043.003, 03.043.004... View More. PRODUCT CODES. DESCRIPTION. The TN-ADVANCED™ Tibial Nailing System (TNA) is an intramedullary nailing system for tibia fractures. This fixation system features design improvements to address previously unmet challenges …SYNTHES USA AIMING ARM FOR 3.5MM VA-LCP PROXIMAL TIBIA PLATE PLATE, FIXATION, BONE: Back to Search Results: Catalog Number 03.127.009: Device Problem Failure to Align (2522) ... It was reported that during a proximal tibial plate insertion on (b)(6) 2015 the surgeon noticed that the aiming arm did not line up with the standard tibial plateau ...…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Variable Angle LCP™ Proximal Tibia Plate (3.5. Possible cause: The 04.004.643S | Synthes 12MM TI Tibial Na...

The Variable Angle Locking Patella Plating System was developed to reduce these complication rates. The system offers two plating solutions in titanium and stainless steel: 2.7 mm Variable Angle Locking Anterior Patella Plates. 2.4/2.7 mm Variable Angle Locking Lateral Rim Patella Plates. The most appropriate plate version can be chosen based ...4.5 mm LCP® Proximal Tibia Plates - synthes.vo.llnwd.netThe Universal Small Fragment (USF) System is intended to be used for small bone trauma, including anatomy such as Shoulder, Clavicle, Elbow, Tibia and Fibula. The core set can support any DePuy Synthes 2.7mm or 3.5mm non-locking, LCP® or VA LCP® Implant System. Training topics for USF. System Trays. Instruments.

In contrast, the capturing rates boosted to 76.4% and 71.5% when utilizing VA screws in the DePuy Synthes VA-LCP and the Biomet plate. The high-frequency uncaptured areas tended to concentrate on the rim of the posterolateral wall and were mainly distributed in the posterior 1/2 to 3/4 of the parallel position of the fibula head.Product Codes: 02.118.002, 02.118.002S, 02.118.003... View More. PRODUCT CODES. DESCRIPTION. The 2.7 mm/3.5 mm VA LCP™ Ankle Trauma System is a comprehensive plating system that merges variable angle locking screw technology with conventional plating techniques for fixation of the ankle when growth plates have fused. Product Specifications.

ap calc frq 2016 BitTorrent isn’t the quiet haven it once was. These days, everyone’s looking to throttle your connection, spy on what you’re downloading, or even send you an ominous letter. If you...VA-LCP® MEDIAL COLUMN FUSION PLATES 3.5 VA LOCKING CALCANEAL PLATES 2.7 VA-LCP Ankle Trauma System 2.7/3.5 VA-LCP Anterior Clavicle Plate VA-LCP Condylar Plate 4.5/5.0 VA-LCP Distal Humerus Plates 2.7/3.5 VA-LCP Olecranon Plates 2.7/3.5 VA-LCP Proximal Tibial Plate 3.5 VA-Locking Intercarpal Fusion System grandlesunimas schedule eastern The Synthes 3.5 mm VA-LCP® Proximal Tibia Plate is part of the VA-LCP Periarticular Plating System which merges variable angle locking screw technology with conventional plating techniques. The 3.5 mm VA-LCP Proximal Tibia Plate System has many similarities to standard locking fixation methods, with a few important improvements.The following tips can help you complete Synthes Va Proximal Tibia Inventory easily and quickly: Open the form in the full-fledged online editing tool by clicking Get form. Fill in the necessary fields that are colored in yellow. Press the arrow with the inscription Next to move from box to box. Go to the e-signature solution to put an ... dmv in louisburg BitTorrent isn’t the quiet haven it once was. These days, everyone’s looking to throttle your connection, spy on what you’re downloading, or even send you an ominous letter. If you... wareham obituariescarol serling net worthcostco locations in houston tx Use the Torque Limiter 1.5 Nm (511.115) and the Screwdriver Shaft (Hex 314.030, Stardrive 314.116) for the motor-driven insertion of the locking screw. Stop the motor before locking, fix the torque limiter and the screw-driver shaft to the Handle with Quick Coupling (311.431) and tighten the screw. After one click, the optimal torque is reached. embry riddle daytona calendar The VA-LCP Elbow Plating System reduces the risk of soft tissue irritation through focused improvements to the implant design and profile. Plate design Optimized metaphyseal plate profile, together with rounded edges and an improved anatomical plate fit minimize the prominence of the construct without compromising stability. Cross-section of ...03.231.016. Sechskantschraubenzieher-Einsatz. 4.0 mm, durchbohrt, Länge 180 mm, für Sechskantkupplung 6.0 mm. Ein Loch im Zielbügelaufsatz auswählen und durch das Loch eine Inzision anlegen. Um die durchbohrte VA-Verriegelungsschraube 5.0 mm in variablem Winkel einzubringen, die VA-Führungsbüchse. yorkies for sale in kansas citynationals park seating chart with seat numbersloyal source jobs in texas Clinical Resources. Surgical Technique Guide. Instructions for Use. -. The 2.4mm LCP Distal Radius System is part of the Locking Compression Plate System that merges locking screw technology with conventional plating techniques.